Our Data Center - Infinite Chain

It all starts with a concept.

We are developing Toplita Technology Park - the first HYPERSCALE & largest data center complex in Romania with the lowest carboon footprint possible

shared

Lowest PUE with GREEN Energy

Demand for IT capacity continues to grow rapidly across the globe, which has driven the need for more standardized, industrialized approaches to data center construction and component assembly. We have scrambled to apply new processes and disciplines, expand and re-organize supply chains, deploy prefabricated components, and, where possible, reduce cost overheads, variation and complexity.

These approaches have led us to the adoption of a different concept for design, location and technologies used. Unique in our approach, we will be able to cool our data center with year round full or partial free cooling. Mechanical cooling will only be required to top-up the partial cooling element only when the outdoor temperature are excessively high. Another area enabling reduced power usage is the use of state-of-the art UPS and electrical systems.

The PUE achievable for a specific data center will depend on local climate, including outside air temperature, humidity and risk for airborne pollution. Taking into account all the specific aspects of the industry, we decided to analyze possible locations for the construction of a data center in Romania. The “winning” location was identified in Toplița Municipality, Harghita County, as it met all the necessary criteria to obtain a high efficiency .

Our Data Center Design

Toplita Technology Park Modular Concept Design

Toplita Technology Park Specifications

Power Infrasctructure

  • Total data center power capacity (MW): 50 MW fully completed
  • Power density per rack (kW): from 10 kW to 20 kW
  • Two independent feeds from the National Grid (SEN)
  • Substation dedicated to data center facility
  • Substation feeds enter the property via diverse routes
  • Substation feeds enter the data center via diverse routes
  • Underground, end-to-end feeds
  • Each UPS has an A and B utility feed
  • UPS designed with a maintenance bypass, allowing live full
    replacement
  • Maintenance bypass is UPS protected 
  • Diesel fuel onsite underground storage
  • Backup generators
  • Battery backup capacity at load for 12 minutes
  • Guaranteed PUE year-round: below 1.2

Cooling Infrasctructure

  • Hot row/cold row segregation
  • Water cooled chilled water design
  • Indirect Adiabatic Free Cooling
  • VFD Chillers
  • VFD CRAHs
  • VFD chilled water pumps
  • Make up water lines feeding cooling towers are encased
  • Two separate water feeds into the data center
  • Separate feeds delivered from diverse sources and diverse paths replacement
  • Condenser water system paralleled
  • Chillers paralleled
  • Chilled water pumps paralleled
  • Chilled water distribution triple looped
  • Guaranteed PUE year-round: below 1.2

Network Infrasctructure

  • Carrier-neutral data center
  • Free cross-connects
  • Dark fiber available
  • Private data transport available
  • High quality blended internet service offered
  • Internal meet-me-room (MMR) or telecom exchange point
  • Core network equipment protected from customer access
  • Telecom conduit enters facility through:
    • Underground and concrete encased
    • Dual paths
    • Diverse paths
    • Diverse entry points
  • Data transport is diverse and redundant replacement
  • DDoS Mitigation Services
  • 100% SLA on all elements of data center provider supplied
    connectivity

Security Infrasctructure

  • Facility is staffed 24/7/365
  • Protected by perimeter fencing
  • Centralized security at loading docks and main entry points
  • Digital video recording of all personnel at all time
  • Digital video recording archived
  • Custom security solution available for dedicated access
  • External mechanical yard components within a fenced area
  • Biometric controls used to gain access
  • High-Sensitivity Smoke Detection (HSSD)
  • Dual-interlock, multi-zoned pre-action dry pipe systems
  • Data center is a master planned, purpose built facility
  • Each generator located in secure, isolated location
  • Each UPS system located in secure, isolated rooms
  • Power equipment protected from customer access
  • Facility is wholly owned by provider
  • Secured parking 

Geography

  • 6° Celsius (42.8° F) average annual temperature (similar to the Nordics)
  • Altitude of 650 m above sea level
  • Located farther than one mile from highway 
  • Located farther than one mile from train tracks
  • Located outside of moderate and high natural disaster risk zones
  • 10 years free of natural hazards and severe weather events
  • No risk for:
    • Flood
    • Hurricane
    • Tornado
    • Tsunami
  • Lowest seismic risk in the region

Service and Support

  • Onsite staff 24x7x365
  • Technical staff available for support, including engineers
  • Rack and stack
  • Cabling
  • Power cycling
  • Structured cabling
  • Staging area available
  • Secure storage
  • Managed shipping and receiving
  • Disaster recovery options available
  • Dedicated seats 
  • Workstations with hardwire and wireless access 
  • Conference rooms with projectors available for use 

Energy Infrastructure

Unprecedented features bring remarkable power.
Dedicated substation 110kV/63 MVA,  fed from two 110kV power lines form the national main grid.

Our Location Advantages

Lowest seismic risk in the region.
Best climate with 6° Celsius (42.8° F) average annual temperature, similar to the Nordic European Region.

Romania Seismic Map

Romania Climate Map